Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
BMJ Open ; 12(11): e064038, 2022 11 03.
Article in English | MEDLINE | ID: covidwho-2097994

ABSTRACT

OBJECTIVES: This body of work aimed to elicit ambulance service staff's perceptions on the barriers and facilitators to adoption, and clinical utility of incorporating rapid SARS-CoV-2 testing during ambulance assessments. DESIGN: A mixed-methods survey-based project using a framework analysis method to organise qualitative data. SETTING: Emergency and non-emergency care ambulatory services in the UK were approached to take part. PARTICIPANTS: Current, practising members of the UK ambulance service (paramedics, technicians, assistants and other staff) were included in this body of work. RESULTS: Survey 1: 226 responses were collected between 3 December 2020 and 11 January 2021, 179 (79.2%) of which were completed in full. While the majority of respondents indicated that an ambulance-based testing strategy was feasible in concept (143/190, 75.3%), major barriers to adoption were noted. Many open-ended responses cited concerns regarding misuse of the service by the general public and other healthcare services, timing and conveyance issues, and increased workloads, alongside training and safety concerns. Survey 2: 26 responses were received between 8 February 2021 and 22 February 2021 to this follow-up survey. Survey 2 revealed conveyance decision-making, and risk stratification to be the most frequently prioritised use cases among ambulance service staff. Optimal test characteristics for clinical adoption according to respondents were; accuracy (above 90% sensitivity and specificity), rapidity (<30 min time to results) and ease of sample acquisition. CONCLUSIONS: The majority of commercially available lateral flow devices are unlikely to be supported by paramedics as their duty of care requires both rapid and accurate results that can inform clinical decision making in an emergency situation. Further investigation is needed to define acceptable test characteristics and criteria required for ambulance service staff to be confident and supportive of deployment of a SARS-CoV-2 test in an emergency care setting.


Subject(s)
COVID-19 , Emergency Medical Services , Humans , Ambulances , SARS-CoV-2 , COVID-19 Testing , Feasibility Studies , COVID-19/diagnosis , Surveys and Questionnaires , Point-of-Care Testing
2.
Emerg Med J ; 39(7): 563-564, 2022 07.
Article in English | MEDLINE | ID: covidwho-1728836

Subject(s)
COVID-19 , SARS-CoV-2 , Humans
3.
J Mol Diagn ; 24(4): 320-336, 2022 04.
Article in English | MEDLINE | ID: covidwho-1895234

ABSTRACT

Previous studies have described reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal/oropharyngeal swab and saliva samples. This multisite clinical evaluation describes the validation of an improved sample preparation method for extraction-free RT-LAMP and reports clinical performance of four RT-LAMP assay formats for SARS-CoV-2 detection. Direct RT-LAMP was performed on 559 swabs and 86,760 saliva samples and RNA RT-LAMP on extracted RNA from 12,619 swabs and 12,521 saliva samples from asymptomatic and symptomatic individuals across health care and community settings. For direct RT-LAMP, overall diagnostic sensitivity (DSe) was 70.35% (95% CI, 63.48%-76.60%) on swabs and 84.62% (95% CI, 79.50%-88.88%) on saliva, with diagnostic specificity of 100% (95% CI, 98.98%-100.00%) on swabs and 100% (95% CI, 99.72%-100.00%) on saliva, compared with quantitative RT-PCR (RT-qPCR); analyzing samples with RT-qPCR ORF1ab CT values of ≤25 and ≤33, DSe values were 100% (95% CI, 96.34%-100%) and 77.78% (95% CI, 70.99%-83.62%) for swabs, and 99.01% (95% CI, 94.61%-99.97%) and 87.61% (95% CI, 82.69%-91.54%) for saliva, respectively. For RNA RT-LAMP, overall DSe and diagnostic specificity were 96.06% (95% CI, 92.88%-98.12%) and 99.99% (95% CI, 99.95%-100%) for swabs, and 80.65% (95% CI, 73.54%-86.54%) and 99.99% (95% CI, 99.95%-100%) for saliva, respectively. These findings demonstrate that RT-LAMP is applicable to a variety of use cases, including frequent, interval-based direct RT-LAMP of saliva from asymptomatic individuals who may otherwise be missed using symptomatic testing alone.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , RNA, Viral/analysis , RNA, Viral/genetics , SARS-CoV-2/genetics , Saliva , Sensitivity and Specificity
4.
Journal of Patient Safety and Risk Management ; : 25160435211054207, 2021.
Article in English | Sage | ID: covidwho-1523271

ABSTRACT

IntroductionSuccessful adoption of POCTs (Point-of-Care tests) for COVID-19 in care homes requires the identification of ideal use cases and a full understanding of the contextual and usability factors that affect test results and minimise biosafety risks. This paper presents a scoping-usability and test performance study of a microfluidic immunofluorescence assay for COVID-19 in care homes.MethodsA mixed-methods evaluation was conducted in four UK care homes to scope usability and to assess the agreement with qRT-PCR. A dry run with luminescent dye was conducted to explore biosafety issues.ResultsThe agreement analysis was conducted on 227 asymptomatic participants (159 staff and 68 residents) and 14 symptomatic participants (5 staff and 9 residents). Asymptomatic specimens showed 50% (95% CI:1.3%?98.7%) positive agreement and 96% (95% CI: 92.5%?98.1%) negative agreement with overall prevalence and bias-adjusted Kappa (PABAK) of 0.911 (95% CI: 0.857?0.965). Symptomatic specimens showed 83.3% (95% CI: 35.9%?99.6%) positive agreement and 100% (95% CI: 63.1%?100%) negative agreement with overall prevalence and bias-adjusted Kappa (PABAK) of 0.857 (95% CI: 0.549?1). The dry run highlighted four main sources of contamination that led to the modification of the standard operating procedures. Simulation post-modification showed no further evidence of contamination.ConclusionCareful consideration of biosafety issues and contextual factors associated with care home are mandatory for safe use the POCT. Whilst POCT may have some utility for ruling out COVID-19, further diagnostic accuracy evaluations are needed to promote effective adoption.

5.
Emerg Med J ; 39(1): 70-76, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1504636

ABSTRACT

Point-of-care tests for SARS-CoV-2 could enable rapid rule-in and/or rule-out of COVID-19, allowing rapid and accurate patient cohorting and potentially reducing the risk of nosocomial transmission. As COVID-19 begins to circulate with other more common respiratory viruses, there is a need for rapid diagnostics to help clinicians test for multiple potential causative organisms simultaneously.However, the different technologies available have strengths and weaknesses that must be understood to ensure that they are used to the benefit of the patient and healthcare system. Device performance is related to the deployed context, and the diagnostic characteristics may be affected by user experience.This practice review is written by members of the UK's COVID-19 National Diagnostic Research and Evaluation programme. We discuss relative merits and test characteristics of various commercially available technologies. We do not advocate for any given test, and our coverage of commercially supplied tests is not intended to be exhaustive.


Subject(s)
COVID-19 , Humans , Point-of-Care Testing , SARS-CoV-2
6.
Age Ageing ; 50(5): 1464-1472, 2021 09 11.
Article in English | MEDLINE | ID: covidwho-1196971

ABSTRACT

INTRODUCTION: Reliable rapid testing for COVID-19 is needed in care homes to reduce the risk of outbreaks and enable timely care. This study aimed to examine the usability and test performance of a point of care polymerase chain reaction (PCR) test for detection of SARS-CoV-2 (POCKITTM Central) in care homes. METHODS: POCKITTM Central was evaluated in a purposeful sample of four UK care homes. Test agreement with laboratory real-time PCR and usability and used errors were assessed. RESULTS: No significant usability-related hazards emerged, and the sources of error identified were found to be amendable with minor changes in training or test workflow. POCKITTM Central has acceptable sensitivity and specificity based on RT-PCR as the reference standard, especially for symptomatic cases.Asymptomatic specimens showed 83.3% (95% confidence interval (CI): 35.9-99.6%) positive agreement and 98.7% negative agreement (95% CI: 96.2-99.7%), with overall prevalence and bias-adjusted kappa (PABAK) of 0.965 (95% CI: 0.932- 0.999). Symptomatic specimens showed 100% (95% CI: 2.5-100%) positive agreement and 100% negative agreement (95% CI: 85.8-100%), with overall PABAK of 1.Recommendations are provided to mitigate the frequency of occurrence of the residual use errors observed. Integration pathways were discussed to identify opportunities and limitations of adopting POCKIT™ Central for screening and diagnostic testing purposes. CONCLUSIONS: Point-of-care PCR testing in care homes can be considered with appropriate preparatory steps and safeguards. Further diagnostic accuracy evaluations and in-service evaluation studies should be conducted, if the test is to be implemented more widely, to build greater certainty on this initial exploratory analysis.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Point-of-Care Systems , Point-of-Care Testing , Polymerase Chain Reaction , Sensitivity and Specificity
7.
J Infect ; 81(3): 427-434, 2020 Sep.
Article in English | MEDLINE | ID: covidwho-628179

ABSTRACT

BACKGROUND: Significant nosocomial transmission of SARS-CoV-2 has been demonstrated. Understanding the prevalence of SARS-CoV-2 carriage amongst HCWs at work is necessary to inform the development of HCW screening programmes to control nosocomial spread. METHODS: Cross-sectional 'snapshot' survey from April-May 2020; HCWs recruited from six UK hospitals. Participants self-completed a health questionnaire and underwent a combined viral nose and throat swab, tested by Polymerase Chain Reaction (PCR) for SARS-CoV-2 with viral culture on majority of positive samples. FINDINGS: Point prevalence of SARS-CoV-2 carriage across the sites was 2.0% (23/1152 participants), median cycle threshold value 35.70 (IQR:32.42-37.57). 17 were previously symptomatic, two currently symptomatic (isolated anosmia and sore throat); the remainder declared no prior or current symptoms. Symptoms in the past month were associated with threefold increased odds of testing positive (aOR 3.46, 95%CI 1.38-8.67; p = 0.008). SARS-CoV-2 virus was isolated from only one (5%) of nineteen cultured samples. A large proportion (39%) of participants reported symptoms in the past month. INTERPRETATION: The point-prevalence is similar to previous estimates for HCWs in April 2020, though a magnitude higher than in the general population. Based upon interpretation of symptom history and testing results including viral culture, the majority of those testing positive were unlikely to be infectious at time of sampling. Development of screening programmes must balance the potential to identify additional cases based upon likely prevalence, expanding the symptoms list to encourage HCW testing, with resource implications and risks of excluding those unlikely to be infectious with positive tests. FUNDING: Public Health England.


Subject(s)
Betacoronavirus , Coronavirus Infections/epidemiology , Disease Transmission, Infectious/statistics & numerical data , Health Personnel/statistics & numerical data , Pneumonia, Viral/epidemiology , Adult , Aged , COVID-19 , Coronavirus Infections/diagnosis , Coronavirus Infections/transmission , Cross-Sectional Studies , England , Female , Humans , Male , Medical Staff, Hospital/statistics & numerical data , Middle Aged , Pandemics , Pneumonia, Viral/diagnosis , Pneumonia, Viral/transmission , Prospective Studies , RNA, Viral , Real-Time Polymerase Chain Reaction , SARS-CoV-2 , Surveys and Questionnaires , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL